Product Overview

Our team of scientists and engineers have been helping prevent catastrophic fires since 2010. We’ve developed a suite of product solutions designed specifically to meet the fire protection needs of today’s residential and multi-family wood construction projects. Use the interactive tool below to learn more about BarrierTek products and solutions.
  • treated with ProTEKtor II® on one side and installed with the treated side facing down to joist
  • certified CAN/ULC-S102
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating for quality and reliability of performance
  • specifically designed for harsh climates
  • no special equipment required for cutting
  • conventional installation with no special installation requirements
  • for multi-family applications, sheathing is treated on one side with ProTEKtor II® and installed with the treated side facing inward
  • For detached single-family applications, wall sheathing is treated on one side with ProTEKtor® PG and installed with the treated side facing outward in new developments. Infill construction must have the treated side facing inward unless explicitly stated.
  • certified CAN/ULC-S102
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating for quality and reliability of performance
  • specifically designed for harsh climates
  • no special equipment required for cutting
  • conventional installation with no special installation requirements
  • I-joists are fully treated on web and flange with ProTEKtor IIJ® and installed using conventional joist hanging practices
  • certified CAN/ULC-S102
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating for quality and reliability of performance
  • specifically designed for harsh climates
  • no special equipment required for cutting
  • all internal studs, headers, backing, bracing, and blocking are fully treated on all sides
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating for quality and reliability of performance
  • specifically designed for harsh climates
  • no special equipment required for cutting
  • conventional installation with no special installation requirements
  • all truss lumber, bracing and blocking are fully treated with AtTEK on all sides
  • part of NFPA13 alternative to traditional attic sprinkler systems and dry/glycol systems in confined spaces
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating prior to assembly of trusses for quality and reliability of performance
  • specifically designed for harsh climates and handling
  • no special equipment required for cutting
  • treated with AtTEK on one side and installed with the treated side facing down to the truss
  • part of NFPA13 alternative to traditional attic sprinkler systems and dry/glycol systems in confined spaces
  • non-toxic, non-carcinogenic, and completely safe to handle – compliance with LEED standards for emissions
  • factory applied coating for quality and reliability of performance
  • specifically designed for harsh climates
  • no special equipment required for cutting
  • conventional installation with no special installation requirements

Product Details

Panel - Large Project Page

Panels - Subfloors & Wall Sheathing

ProTEKtor® II & ProTEKtor® PG

ProTEKtor® II OSB and plywood sheets have a proprietary factory-applied coating that turns the wood panels on your multi-family project into fire-resistant shields. Wall sheathing is treated on one side and installed with the treated side facing inward and sub floors are treated on one side and installed with the treated side facing down to the joist.

ProTEKtor® PG OSB and plywood sheets are specifically formulated to meet the toughest of narrow lot and adjacent property detached construction requirements. For detached single-family applications, wall sheathing is treated on one side with ProTEKtor® PG and installed with the treated side facing outward in new developments. Infill construction must have the treated side facing inward unless explicitly stated.

IJoists- Large Project Page

I-Joists

ProTEKtor® II

In the event of a fire, an untreated joist’s web burns through about 70% faster than its top and bottom chords. With a compromised web, the joist fails as it cannot support the engineered design load. Joists are fully coated on the web and flange with ProTEKtor® II and installed using normal joist hanging practices and methods.

Lumber - Post Graphic

Dimensional lumber

ProTEKtor® IID

All internal studs, headers, other framing, bracing and blocking are treated with ProTEKtor® IID before it reaches your site. BarrierTek treated lumber is safe to handle and requires no special installation requirements making ProTEKtor® IID an easy fit in to your fire prevention strategy.
AtTEk - Large Project Page

Attics - Roof Trusses & Sheathing

AtTEK®

AtTEK® meets all of the testing required to be meet NFPA-13 and is becoming a welcomed choice for builders, developers, and occupants seeking to lower costs and de-risk fire-suppression in attic and confined space. AtTEK acts as an active fire-protection system, requiring no mechanical systems of sensors to do the job. And with no ongoing maintenance, servicing, or certification like that required with sprinklers, AtTEK® eliminates one of the largest pain points for property managers and owners.

With AtTEK®, enjoy peace of mind with no fires, no floods, and no maintenance.

All truss lumber, bracing and blocking are treated on all sides. Sheathing is treated with AtTEK on one side and installed with the treated side facing down to the truss.

Product Attributes

All BarrierTek products have the following attributes: